Digital Transducer Readout
| The E-405 programmable Smart Digital
Indicator is a single-channel digital readout with a "99999" display.
It sends a direct voltage of 5 or 10 V to a load cell, pressure
or displacement transducer, or temperature transducer. The transducer
then sends a millivolt signal back to the readout, based on the
amount of stress or strain applied to the transducer. The E-405
then takes the millivolt signal and converts it into engineering
units based on the calibration factors stored in memory. The direct
display of readings in engineering units is very convenient for
the operator, increases productivity, and minimize the potential
for recording errors in the lab.
The E-405 has fast control responses (60 readings/sec),
true peak reading capability, and an analog output that accurately
tracks the signal input. It has an adaptive digital filter that
automatically selects the best time constant for minimum noise,
and yet responds rapidly to an actual change in signal level. |
When purchased with a Durham Geo transducer,
the E-405 is supplied with a NIST Traceable Certificate of Calibration.
The front panel
allows user set-up and re-calibration by push buttons. The software
which accompanies the RS-232 and RS-485 options, allows for recalibration
through a computer.
Optional
accessories include RS-232, Relay Board, and Analog "plug
in" boards which allow the E-405 to output data to plotters
or computers. An RS-485 board is also available to connect up to
31 meters using 4-wire phone cable (also known as daisy chaining).
This feature allows the laboratory manager customize his data acquisition
from 1 to 31 channels, and use the optional RS-485 to RS-232 converter
to bring the data into the "Com Port" on his computer.
The E-405 can be customized for a great variety of industrial
and testing industry tasks. If you have a special application,
please call us to discuss your requirements.
|

The
example on the right shows three E-405 Readouts (connected to
a load cell as well as alinear displacement and pore pressure transducers)
on a permeability / triaxial cell. |
Standard Features
|

|
Plug in Option Boards.
|

|
Five Full Digits BiDirectional
|

|
50-60 Readings Per Second
|

|
True-Peak Hold, Auto Tare, and Automatic
|

|
Adaptive Digital Filter
|

|
Isolated 5, 10, or 24 V (dc) Excitation
|

|
Worldwide AC/DC Power
|

|
NEMA 4 Lens Cover
|

|
0.56" High Digits
|

|
User Selectable Scaling, Front Panel Programming
|
Optional Features
|

|
Dual 10 A Relay Alarm Board
|

|
Open Collector Outputs
|

|
Isolated RS232 or RS485 or Parallel BCD
|

|
Computer Interface
|

|
Analog Outputs 0-20 mA, or 5 to 10 V(dc)
|
Data Sheet (68 kb) >>
 |
 |
E-405
|
Smart
Digital Indicator
|
Related Items:
EZ-DAQ 8-Channel Data Acquisition Readout
Transducers,
Readouts, Indicators
Calibration. Have your proving rings, load cells,
pressure gauges and other measuring devices in the laboratory been
calibrated
recently?
If not, give our calibration department
a call. They will be glad to provide a quotation for your calibration
needs.
|
|