Active Remediation |
 |
F.A.P. Plus™ ZW system — Active pneumatic skimming system for
LNAPL or DNAPL recovery, recovery of a wide range of products from light-end hydrocarbons to more viscous products such
as # 6 heating oils; 2 in or larger wells. See how it works. |
 |
Pneumatic Tank Full Shut Off Device
— Shuts off fluid supply to remediation tanks when full. |
 |
SolarNAPL — solar-powered compressor system for use with direct free product recovery
pumps. May be configured for LNAPL or DNAPL recovery, gas condensate recovery, groundwater purging or air sparging.
SolarSPARGE — configuration for air sparging applications. |
 |
Product/Water Interface Probe — detects and measures the thickness of floating or sinking products.
Detects the presence of water in storage tanks. 7/16 or 5/8 in probe for use in small wells. |
Passive Remediation |
 |
Passive Skimmer — for passive recovery of free phase product (LNAPL) such as gasoline,
diesel and jet fuel. Used when minimal product is present and slow recovery rates are expected. For 2 in or larger wells.
May be upgraded to an active system by adding the F.A.P. Plus™ system. Floating inlet automatically adjusts
to water table changes. |
 |
SoakEase™ — selective absorbent for immediate response or minimal product. Used for
free phase product such as gasoline, diesel and jet fuel. |
| |
Petro-Bailer™ — low cost passive skimmer with a fixed product inlet. For passive
LNAPL recovery in 2 in or larger wells.
CarboBailer™ — Bailer used to manually collect non-emulsified hydrocarbon liquids
(such as gasoline and jet fuel) from wells, drums and tanks. |
Submersible
Pumps |
 |
MVP IV Pneumatic Pumps — controlerless air lift pump for 4" and larger wells. Used to transfer
fluids to the surface from depths of up to 200 ft (61 m). Recommended for dissolved phase, total fluids, plume control, dewatering,
leachate. See how the bottom-loading and top-loading pumps
work.
MVP Pump — low cost version of the MVP IV.
MVP LS and LD Pumps — for use in landfills to recover leachate or gas condensate.
Pump Guides — to prevent pump hang-ups on internal pipe upsets.
Well Seals — for landfill leachate and gas wells. |

|
 |
Evacuator II™ — a high flow, air lift, controlerless pump for pumping total fluids,
dissolved phase, DNAPL and leachate. Also used for plume control and dewatering. For 2 in and larger wells. See how the bottom-loading and top-loading pumps
work. |

 |
SEP IV — electric pumping system for high flows. Recommended for continuous operation in the recovery of contaminated groundwater or leachate, or to create and maintain a zone of depression. Depths up to 400 ft (122 m).
SEP IV Auto Speed Control System — Electrical level control system to maintain a precise draw-down level in a well for extended periods.
PumpSaver — pump monitor designed to protect single phase pumps from dry wells, dead head, jammed impellers, and over/under voltage conditions. |
 |
SepTek System — mechanical liquid level sensing system for controlling electrical submersible pumps. In conjunction with hate SEP IV or other electrical pump, it maintains a precise draw-down level in a well for extended periods. |
Solar Remediation |
 |
SolarNAPL — solar-powered compressor system for use with direct free product recovery pumps. May be configured for LNAPL or DNAPL recovery, gas condensate recovery, groundwater purging or air sparging.
SolarSPARGE — configuration for air sparging applications. |
Low Flow Sampling What's New and Why? |
 |
MBP Mini Bladder Pumps — specifically designed for low-flow groundwater purging and sampling in Sch 40 wells 1/2 in and larger.
Mini PVC Bladder Pump for low-flow portable or dedicated sampling when stainless steel is not required.
Dedicated Bladder Pumps to improve sample quality. |
Ground Water Purging and Sampling |
 |
Peristaltic pump — 12 V portable pump for sampling and purging to 25 ft. Recommended for sampling direct-push wells, streams and ponds, tanks, drums,
manholes, waste water. features digital control and display for repeatability. |
 |
DC purging pump — economical submersible pump for purging, sampling and developing wells to depths of 60 ft (18 m). |
 |
Diffusion Sampler — for passive VOC sampling at discrete intervals in ground water (without bailing or purging). |
 |
HydraSleeve Sampler Sleeve — inexpensive, disposable sampler for no-purge sampling of low-yield wells.
Bailers — single-use bailers and SUPERBAILERs |
| |
|
 |
12 V Sampling Pumps — Monsoon and SS-Mega-Monsoon are high performance submersible pumps for pumping depths of 120 and 200 ft respectively. Powered by a 12 V automotive battery. |
 |
Arch Pneumatic Pump™ — for well development in 2 in and larger wells.
|
Passive Soil Vapor Extraction (PSVE) |
 |
BaroBall valve allows passive removal of vapors from the unsaturated soil zone. |
Support Equipment |
| |
Air Compressors and air dryers — We can supply air compressors for all types of environmental applications, from 3/4 hp oil-less
designs for groundwater sampling to 15 hp models for remediation projects. |
 |
Cap Cop™ — protection vaults for traffic areas. Will support a 10,000 lb single axle wheel load.
|
 |
Hand augers and drive samplers — for grabbing soil samples in shallow holes ( up to 5 ft) to study soil contamination. |
Instrumentation |
 |
Water Level Indicators — to measure water level in stand pipes or wells. Simple, effective, direct readings. cables graduated in ft or in. Cable lengths to 1000 ft. |
 |
Product/Water Interface Probe — detects and measures the thickness of floating or sinking products. Detects the presence of water in storage tanks. 7/16 or 5/8
in probe for use in small wells. |
 |
Vented Pressure Transducer — vented pressure transducer for monitoring water levels in wells and standpipes, and stilling basins installed in reservoirs and
streams. Ideal for data logging when used in conjunction with the Mini-Logger.
VW Mini-Logger (PDF 299 KB) — low-cost data logger designed to monitor a single VW piezometer. Runs up to 6 months and can store up to 8000 readings. |
If you have a specific site in mind, please fill the Remediation Site Assessment Form or the Sampling
Pump Requirements Form (PDF 126 KB) to provide us with specific and detailed information. One of our Technical Support Member will evaluate the information and suggest a site solution. |